0.eap-banner.jpg

EAP Syringe Pump

Microfluidic Injector

Industrial design - user research - concept generation - storyboarding - ergonomics - prototyping

 An electroactive polymer (EAP) syringe pump for microfluidic injections. A more cost effective, mechanically simpler and more intuitive system for surgeons.

An electroactive polymer (EAP) syringe pump for microfluidic injections.
A more cost effective, mechanically simpler and more intuitive system for surgeons.

 In cell therapy operations, microscopic volumes of low viscosity fluids are delivered to the brain through extremely thin and long steel needles. Very precise syringe pumps that control the flow rates and injection volumes of these fluids are requir

In cell therapy operations, microscopic volumes of low viscosity fluids are delivered to the brain through extremely thin and long steel needles.
Very precise syringe pumps that control the flow rates and injection volumes of these fluids are required.

 Existing microfluidic syringe pumps have a non-disposable infrastructure, rely on motor-driven mechanisms, require heavy carts for transport, and are very mechanically complex.

Existing microfluidic syringe pumps have a non-disposable infrastructure, rely on motor-driven mechanisms, require heavy carts for transport, and are very mechanically complex.

Electroactive Polymers (EAPs) are thin films that provide dynamic movement upon electrical stimulation.

As a material-driven design project, I explored several concept mechanisms to integrate EAPs into these systems, to improve the user experience for surgeons.

 Visualizing concept directions for using EAPs as mechanical actuation.

Visualizing concept directions for using EAPs as mechanical actuation.

 Proof-of-concept model to gain surgeon feedback, test handheld ergonomics, and establish touch points.  Electrical current runs through the EAP, it flexes against the housing, and squeezes an inner flexible tube which holds a disposable saline sac.

Proof-of-concept model to gain surgeon feedback, test handheld ergonomics, and establish touch points.

Electrical current runs through the EAP, it flexes against the housing, and squeezes an inner flexible tube which holds a disposable saline sac. This sac is ruptured by a double-ended needle to dispense cell fluid accurately and precisely.

 Docking base with needle and saline sac dispenser.

Docking base with needle and saline sac dispenser.

11.eap-final-design.jpg
12.system-interface.jpg

  Operation Procedure Steps.

 Operation Procedure Steps.